Hot-dip galvanizing in WEGAL bath of increased manganese content

WESOŁOWSKI J.

MALARA S.

Instytut Metali Nieżelaznych, Gliwice

The results of hot-dip galvanizing of low-silicon steel (08X grade) and reactive steel (S235JRG2 grade) samples in zinc bath made of tin-free WEGAL alloy with manganese content increased to 0.2% (ZnAl0.1Ni0.1Mn0.2) have been presented. The researched WEGAL alloy microstructure and phase composition were shown. Its melting point was determined basing on thermal analysis of solidification. Galvanizing tests were performed at the temperature of 445°C, with retention time – 10 min. Analysis of tests results comprised assessment of coatings microstructure and thickness. The manual bending tests of galvanized samples on steel mandrel (angle 180°, radius 5 mm) were carried out with visual evaluation of samples outside edges. Obtained coatings were characterized by good plasticity and aesthetical appearance. The importance of zinc bath composition on coating growth kinetics has been demonstrated.

Keywords: zinc, zinc alloy, hot-dip galvanizing, zinc coating, zinc bath, WEGAL alloy

2016

Vol. 59, nr 11

s. 390-393

Ref. 12

 


 

DOI: 10.15199/40.2016.11.2

Corrosion tests of positive plates modified by post-production waste mass to be used in SLI lead acid batteries

JANKOWSKA E.

MAJCHRZYCKI W.

Instytut Metali Nieżelaznych oddział w Poznaniu / Institute of Non-Ferrous Metals Division in Poznan

The paper presents electrical and corrosion resistance results of leadacid cells with positive plates produced using waste electrode material as addition to the active mass. The grids used in the study were made of PbCaSn alloy obtained by the expanded metal method. Plates preparation consisted in manual application of the paste with different waste electrode material on the grids. The study shows differences in cells behavior

dependent on the amount of the introduced waste material. In addition, positive plates containing 5 and 10% wt. of waste active mass have higher capacity than a plate with standard formulation. Analyses of the produced positive plates containing waste mass that were submitted to a corrosion test showed no signs of corrosion.

Keywords: lead-acid battery, current collector, corrosion test

2016

Vol. 59, nr 11

s. 394-398

Ref.  23

 


 

CORROSION PROTECTION IN PRACTICE

DOI: 10.15199/40.2016.11.3

Application of modern thermal spraying methods as a key to coatings’ superior functional  properties

SZYMAŃSKI K.

TSC, Krzysztof Szymański, Chełm Śląski

SZCZUCKA –LASOTA B.

Wyższa Szkoła Zarządzania Ochroną Pracy, Katowice

GDESZ M.

Fabryka Kotłów RAFAKO S.A, Racibórz

Basic information about thermal spraying and its varieties has been presented. The authors have pointed out the directions for the further development of thermal spraying methods. Selected information about coating materials used in the methods has been included. The need for using proper quality control assessment methods has been emphasized.

Keywords: protective coatings, thermal spraying, HVOF, wear, corrosion, erosion

2016

Vol. 59, nr 11

s. 399-401

Ref. 9

 


 

CORROSION PROTECTION IN PRACTICE

DOI: 10.15199/40.2016.11.4

Corrosion protection of freight wagons according to EU and VPI regulations

KORDALEWSKA E.

Wagon Service Ostróda Sp. z o.o.

EU regulations and guidelines for the corrosion protection of freight wagons are presented. There are discussed requirements for paint coating of particular construction elements of freight wagons.

Keywords: corrosion, EU regulations, VPI, freight wagon

2016

Vol. 59, nr 11

s. 402-403

Ref. 3

 


 

CORROSION PROTECTION IN PRACTICE

DOI: 10.15199/40.2016.11.5

The investigation of basic technical properties of cement composites impregnated with polymerized sulfur

KSIĄŻEK M.

Politechnika Wrocławska, Wydział Budownictwa Lądowego i Wodnego,

Zakład Materiałów Budowlanych Konstrukcji Drewnianych i Zabytkowych

This paper presents the results of the experimental research and analyses indicating the usefulness of waste of sulfur to the protection against corrosion of cement composites. The research have comprised the composition and the conditions for the formation of materials. The physical and mechanical properties of polymerized sulfur composite have been evaluated. The investigation of basic technical properties of cement composites impregnated with polymerized sulfur were examined.

Keywords: impregnation, cement composites, polymerized sulfur, use of the waste of sulphur, polymerization of sulfur, use of sulfur in the building industry

2016

Vol. 59, nr 11

s. 404-406

Ref. 13